standard | condition | |
---|---|---|
Input Voltage Range | AC85 ~ 215V | AC85 ~ 251v |
Frequency | 50 / 60 Hz(47~63) | |
Efficiency | Min 75% | Vin:100aVac, Vout +29.5V/6.8A, Vout:+5.5V.16.7A |
In-rush Current | 40A or less |
standard | condition | |
---|---|---|
Input Over Voltage Protection | Alarm is generated in case of 215Vac or higher. | |
Input Under Voltage Protection | Alarm is generated in case of 84Vac or lower. |
standard | condition | |
---|---|---|
Voltage Range | ||
Line Regulation | +29.5Vout= 28.91V~30.09V +5.5Vout= 5.39V~5.61V | Vin = 85-215Vac, Load= max Vin = 85-215Vac, Load= max |
standard | condition | |
---|---|---|
Output Over Voltage Protection | +29.5V : 31V~33V +5.5V :5.61V~6.3V | +29.5V, +5.5V+29.5V, +5.5V |
Over Current Protection | +29.5V 105%~230%, +5.5V 105~200% | +29.5V, +5.5V |
standard | condition | |
---|---|---|
Insulation resistance | greater than 10 MΩ when DC500V is applied | Input↔Output, Input↔F.G |
Insulating internal pressure | Allow at least 1 minute for AC2000V application | Input↔Output, Input↔F.G |
standard | condition | |
---|---|---|
Operting Temperature | ||
Storage Temperature |
standard | condition | |
---|---|---|
x x x mm (W X H X D) | ||
Cooling Method |