GAON HIGH TECH

Join

EN

EN

Product

We do our best for customer satisfaction by continuously supplying new technologies and innovative products.

GDA50-4805

Features

  • Input and output over voltage protection
  • Output Over Current Protection ( recover automatically )
  • Thermal protection circuits
  • RoHS Compliant
  • All using long life electrolytic capacitors
  • 100% full load burn-in test
  • Conduction cooling ( from base plate to heat sink)
  • three year warranty

Input specification

standard condition
Input Voltage 48VDC
Efficiency 88% Rated input voltage & max load
Inrush Current (maximum) 20A

Output Specification

standard condition
Rated Output Voltage (VDC) 5VDC
Rated Output Current (A) 10A
Maximum Output Current (A) 20A
Ripple & Noise (maximum) 100mVp-p With elec capacitor 100uF & ceramic capacitor 0.1F
Rising time (maximum) 150mS CR mode, at output voltage 10~90%
Line Regulation (maximum) + / - 2% Input voltage range, max load
Load Regulation (maximum) + / -2% Input voltage , max output current
Dynamic Load Regulation (maximum) + / - 5% Current cycle 2mS, rise/fall time 500㎲, duty 50%

Protection circuit

standard condition
Output Over Voltage recovers automatically works over 125 % of rating output voltage
Output Over Current recovers automatically works over 110% of peak current
Short Circuit min 60s & recovers automatically input voltage , max output current
Reverse Input o
Monitor & Alarm o

Lightning Surge

standard condition
Input to F.G +/- 4.0kv / 333A voltage1.2/50㎲, current 8/20 ㎲ combination
Input to GND +/- 4.0kv / 333A voltage1.2/50㎲, current 8/20 ㎲ combination
GND to F.G +/- 4.0kv / 333A voltage1.2/50㎲, current 8/20 ㎲ combination

Isolation Resistance

standard condition
Input to Output min 50㏁ DC 500V
Input to FG min 50㏁ DC 500V

Dielectric withstand Voltage

standard condition
Input to Output min 60S DC 1000V
Input to FG min 60S DC 1000V

Environment & Others

standard condition
Operating Temperature -30℃ ~ +85℃ humidity 5% ~ 95%
Storage Temperature -40℃ ~ +85℃ humidity 5% ~ 95%
Colling Method forced air
vibration 9.8m/s2 1~5Hz, X,Y,Z 1hour rated input voltage, min load
EMC VCCI CLASS A
Dimension (W X H X D ) 150 X 35 X 50mm